20-23-402. Inspectors employed by insurance companies.
Arkansas Code — all titles (historical 2020) · legal_authorities
20-23-402. Inspectors employed by insurance companies.
(a) Boiler inspectors employed by insurance companies which are authorized to insure boilers in this state shall hold certificates of competency issued by the Boiler Inspection Division as provided in this section and shall:
(1) Inspect internally and externally at least one (1) time annually or within the time granted under § 20-23-203(a) all high pressure steam boilers insured by their respective companies;
(2) Inspect externally one (1) time annually and internally one (1) time every three (3) years every low pressure steam heating boiler insured by their respective companies; and
(3) Inspect unfired pressure vessels biennially.
(b) The insured boilers shall be exempt from all inspections other than those of the respective insurance company inspectors unless there is some evidence that proper inspection is not being made.
(c) Within thirty (30) days following each internal inspection made by its inspectors, each insurance company shall file a copy of the internal inspection report and date of the inspection with the Boiler Inspection Division on forms approved by the Division of Labor.
(d)(1) Each insurance company shall file a report annually of all boilers insured and inspected showing location, owner, state number, and date of last inspection.
(2) The report shall be filed not later than January 30 of each calendar year.
(e)(1) If annual reports are not filed with the Boiler Inspection Division by insurance companies who have insurance on boilers in the State of Arkansas within sixty (60) days from the date they are due inspection, the Boiler Inspection Division shall make the required inspection.
(2) A special inspection fee of one hundred dollars ($100) for each boiler or unfired pressure
Source: Arkansas Code — historical release 78 (November 6, 2020) · 20-23-402
Stored review status: Historical 2020-11-06 source release; later amendments not reconciled; machine-extracted, not independently legally reviewed; source heading status: text_in_historical_source. A text match is a research starting point; applicability is not established.
Issuing source page ↗
Authority boundary: historical statutory source snapshot not current law.
Open the recorded source website ↗
Record provenance
Stable record: arkansas_code:legal_authorities:20-23-402
Source file: gov.ar.code.title.20.odt
Pages: Not recorded – Not recorded
Passage SHA-256: 4fe49a97a57cf4710f081a07a5c9ff50ac273bb7e4dce405c73fca35c1bc5051
Source location: content.xml paragraph 21436
Stored source content
20-23-402. Inspectors employed by insurance companies.
(a) Boiler inspectors employed by insurance companies which are authorized to insure boilers in this state shall hold certificates of competency issued by the Boiler Inspection Division as provided in this section and shall:
(1) Inspect internally and externally at least one (1) time annually or within the time granted under § 20-23-203(a) all high pressure steam boilers insured by their respective companies;
(2) Inspect externally one (1) time annually and internally one (1) time every three (3) years every low pressure steam heating boiler insured by their respective companies; and
(3) Inspect unfired pressure vessels biennially.
(b) The insured boilers shall be exempt from all inspections other than those of the respective insurance company inspectors unless there is some evidence that proper inspection is not being made.
(c) Within thirty (30) days following each internal inspection made by its inspectors, each insurance company shall file a copy of the internal inspection report and date of the inspection with the Boiler Inspection Division on forms approved by the Division of Labor.
(d)(1) Each insurance company shall file a report annually of all boilers insured and inspected showing location, owner, state number, and date of last inspection.
(2) The report shall be filed not later than January 30 of each calendar year.
(e)(1) If annual reports are not filed with the Boiler Inspection Division by insurance companies who have insurance on boilers in the State of Arkansas within sixty (60) days from the date they are due inspection, the Boiler Inspection Division shall make the required inspection.
(2) A special inspection fee of one hundred dollars ($100) for each boiler or unfired pressure vessel inspected, plus mileage and expenses from Little Rock to point of inspection and return not to exceed the current rate authorized by the General Assembly to employees of state agencies who furnish their own transportation, plus any meals and hotel bills incurred shall be charged to the insurance company insuring the boilers or unfired pressure vessels unless an extension of time is granted by the Chief Inspector of the Boiler Inspection Division.
(f) No operating certificate issued for an insured boiler inspected by an insurance company inspector shall be valid after the boiler for which it was issued shall cease to be insured by a company authorized by this state to carry the insurance.
Cross-references
Connections may be documented source relationships, shared citations or nearby passages. Each explains its basis; a connection alone does not establish applicability to your situation.
Arkansas Code — all titles (historical 2020) · legal_authorities
20-23-203. Chief inspector's duty to inspect and enforce.
(a) The Chief Inspector of the Boiler Inspection Division, either personally or by a deputy inspector, shall carefully:
(1)(A) Unless the chief inspector grants an extension of time for good cause, inspect internally and externally one (1) time annually every high pressure steam boiler and steam generating apparatus.
(B) An extension of time under subdivision (a)(1)(A) of this section:
(i) Shall not exceed six (6) months; and
(ii) Shall cause the time period for the next annual inspection to begin on the day following the date of the inspection that was extended;
(2) Inspect externally one (1) time annually and internally one (1) time every three (3) years every low pressure steam heating boiler to the extent permitted by the design and construction of the boiler;
(3) Inspect one (1) time biennially every unfired pressure vessel located in this state that is not excepted from the inspections by this chapter; and
(4) Give the owner or operator of the boiler notice of the time when an internal inspection will be made.
(b) The chief inspector shall have free access at all reasonable times for himself or herself and his or her deputies to any premises in this state where a boiler or pressure piping is being built or where a boiler or pressure piping or power plant apparatus is being installed or operated, for the purpose of ascertaining whether the boiler or piping or apparatus is built, installed, and fitted with the necessary appliances and operated in accordance with this chapter and the rules adopted pursuant to this chapter.
(c)(1) The chief inspector shall enforce the laws of the state governing the use of boilers and unfired pressure vessels. He or she shall examine into and report to the D
Source: Arkansas Code — historical release 78 (November 6, 2020) · 20-23-203
Stored review status: Historical 2020-11-06 source release; later amendments not reconciled; machine-extracted, not independently legally reviewed; source heading status: text_in_historical_source. The source passage cites 20-23-203. This identifies an authority to review, not proof of applicability.